Platelet Reduction after Transcatheter Aortic Valve Implantation: Results from the PORTRAIT Study

Federica Jiritano, Michele Di Mauro,Giuseppe Filiberto Serraino, Pasquale Mastroroberto, Elena Caporali,Enrico Ferrari, Mariusz Kowalewski, Roberto Scrofani,Leonardo Patane, Giuseppe Visicchio,Domenico Paparella, Giosue Falcetta,Andrea Colli,Matteo Matteucci, Giangiuseppe Cappabianca,Francesco Pollari, Theodor Fischlein,Roberto Lorusso

JOURNAL OF CLINICAL MEDICINE(2024)

引用 0|浏览4
暂无评分
摘要
Background: An unexplained condition that follows transcatheter aortic valve implantation (TAVI) is platelet count reduction (PR). According to published research, patients with balloon-expandable valves (BEVs) had a greater PR than those with self-expandable valves (SEVs). Objectives: The purpose of this study was to investigate the incidence and clinical effects of PR following TAVI. Methods: In total, 1.122 adult TAVI patients were enrolled. Propensity score matching was carried out in a 1:1 ratio between patients with BEVs and those with SEVs. The analysis included changes in platelet count, in-hospital mortality, and early postoperative adverse events. Results: Notably, 632 patients were matched (BEV:316; SEV:316). All patients' post-procedural platelet counts changed according to a parabolic curve, using a mixed regression model for repeated analyses (estimate = -0.931; standard error = 0.421; p = 0.027). The platelet count varied comparably in patients with BEVs and SEVs (estimate = -4.276, standard error = 4.760, p = 0.369). The average time for obtaining the nadir platelet count value was three days after implantation (BEV: 146 (108-181) vs. SEV: 149 (120-186); p = 0.142). Overall, 14.6% of patients (92/632) had post-procedural platelet count <100,000/L. There was no difference between the two prosthesis types (BEV:51/316; SEV:41/316; p = 0.266). Thrombocytopenia was found to be significantly linked to blood product transfusions, lengthier stays in the intensive care unit and hospital, and in-hospital mortality. Conclusions: TAVI, irrespective of the type of implanted valve, is linked to a significant but temporary PR. Thrombocytopenia increases the risk of serious complications and in-hospital death in TAVI patients. To explore and clarify the causes and associated effects, further prospective research is necessary.
更多
查看译文
关键词
thrombocytopenia,platelet,transcatheter aortic valve implantation,bioprosthesis,aortic valve
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要