A luminescent terbium(III) probe as an efficient 'Turn-ON' sensor for dipicolinic acid, a Bacillus Anthracis biomarker

NEW JOURNAL OF CHEMISTRY(2022)

引用 1|浏览6
暂无评分
摘要
Extremely hazardous Bacillus Anthracis bacterial endospores comprise dipicolinic acid (DPA) as a universal and major constituent (10(15) molecules per spore, 1 M), which acts as a prominent biomarker. Such highly infectious and lethal pathogens could be maliciously used as biothreat agents or bioweapons in spreading bioterrorism, posing a serious threat to public health and national security. Therefore, a sensitive, selective, and efficient detection or surveillance system is needed to combat the threats of bioterrorism events. Herein, we designed an efficient detection strategy based on a DPA-sensitized time-resolved luminescent (TRL) TbL-probe formulated as [Tb(p-BrPTC)(H2O)(3)](OTf), where p-BrPTC = 4 '-(4-bromophenyl)-[2,2':6 ',2 ''-terpyridine]-6,6 ''-dicarboxylic acid. Our investigation showed an instant optical response of similar to 600-fold enhancement in the luminescence intensity of the D-5(4) -> F-7(5) band upon the equimolar addition of the DPA(2-) biomarker, and the probe eventually acted as a 'Turn-ON' sensor. We successfully recognized and provide evidence of DPA(2-) coordination to the poorly luminescent TbL-probe, resulting in the formation of a strongly luminescent and coordinatively saturated rigid complex whose formation was validated by H-1-NMR titration, TRL titration, and ESI-MS analysis. Further, the DPA(2-) sensing mechanism was supported by monitoring the luminescence excited state lifetime (tau) increase from 140 mu s to 1.41 ms; such a great enhancement strongly suggests their coordination to the TbL-probe. Additionally, the luminescence titration data presents the strong binding affinity of the DPA(2-) biomarker towards the Tb(III)-probe (K-b = 6.67 x 10(6) M-1), making it a highly sensitive and selective sensor. Interestingly, the luminescence response prevails even in the presence of competitive phosphate anions in aqueous media relevant to physiological samples. Most notably, the TRL response of the TbL-probe was found to be highly selective for the DPA(2-) biomarker in the presence of various interfering carboxylic acids, amino acids, and several other bio-analytes, and it could quantitatively detect DPA(2-) up to similar to 54 ppb (0.32 mu M). Overall, the results are quite promising for developing reliable, rapid, and sensitive Ln(III)-based time-resolved luminescence (TRL) probes for anthrax spore detection, and expandable to other biothreat agents having chemically fitting biomarkers for interactions with Ln(III) receptors.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要