Artificial Intelligence-Aided Colonoscopy Does Not Increase Adenoma Detection Rate in Routine Clinical Practice.

The American journal of gastroenterology(2022)

引用 32|浏览28
暂无评分
摘要
The performance of artificial intelligence-aided colonoscopy (AIAC) in a real-world setting has not been described. We compared adenoma and polyp detection rates (ADR/PDR) in a 6-month period before (pre-AIAC) and after introduction of AIAC (GI Genius, Medtronic) in all endoscopy suites in our large-volume center. The ADR and PDR in the AIAC group was lower compared with those in the pre-AIAC group (30.3% vs 35.2%, P < 0.001; 36.5% vs 40.9%, P = 0.004, respectively); procedure time was significantly shorter in the AIAC group. In summary, introduction of AIAC did not result in performance improvement in our large-center cohort, raising important questions on AI-human interactions in medicine.
更多
查看译文
关键词
adenoma detection rate,colonoscopy,intelligence-aided
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper