Sex- and age-specific normal values for automated quantitative pixel-wise myocardial perfusion cardiovascular magnetic resonance.

European heart journal. Cardiovascular Imaging(2023)

引用 5|浏览36
暂无评分
摘要
Fully automated in-line CMR myocardial perfusion mapping produces similar normal values to the published CMR and PET literature. There is a significant increase in rest and stress MBF, but not MPR, in females and a reduction of stress MBF and MPR with advancing age, advocating the use of sex- and age-specific reference ranges for diagnostic use.
更多
查看译文
关键词
cardiovascular magnetic resonance,myocardial perfusion,myocardial perfusion reserve,normal values