Evaluation of adenosine triphosphate bioluminescence-based system in rooms occupied by patients with methicillin resistant Staphylococcus aureus
Infectious Medicine(2022)
摘要
Background
Adenosine triphosphate (ATP)-based monitoring systems can detect the amount of organic matter that remains on hospital surfaces after cleaning. We evaluated an ATP-based monitoring system in assessing contamination of high touched objects in rooms occupied by patients on methicillin resistant S. aureus precautions.
Methods
We compared the ATP to standard aerobic cultures as well as to gloved hand culture to predict risk of healthcare-worker hand contamination.
Results
More than a third of high touch object surfaces were measured unclean with ATP yet only reflects about 5% chance of contaminating healthcare-workers’ hands.
Conclusions
Our study emphasizes the shortcomings of using the ATP system even in pathogen specific environment such as surfaces in methicillin resistant S. aureus rooms.
更多查看译文
关键词
Environment,Healthcare-associated infections,Hand hygiene,Infection prevention,Infection control,MRSA
AI 理解论文