谷歌浏览器插件
订阅小程序
在清言上使用

Evaluation of adenosine triphosphate bioluminescence-based system in rooms occupied by patients with methicillin resistant Staphylococcus aureus

Infectious Medicine(2022)

引用 0|浏览4
暂无评分
摘要
Background Adenosine triphosphate (ATP)-based monitoring systems can detect the amount of organic matter that remains on hospital surfaces after cleaning. We evaluated an ATP-based monitoring system in assessing contamination of high touched objects in rooms occupied by patients on methicillin resistant S. aureus precautions. Methods We compared the ATP to standard aerobic cultures as well as to gloved hand culture to predict risk of healthcare-worker hand contamination. Results More than a third of high touch object surfaces were measured unclean with ATP yet only reflects about 5% chance of contaminating healthcare-workers’ hands. Conclusions Our study emphasizes the shortcomings of using the ATP system even in pathogen specific environment such as surfaces in methicillin resistant S. aureus rooms.
更多
查看译文
关键词
Environment,Healthcare-associated infections,Hand hygiene,Infection prevention,Infection control,MRSA
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要