Ultra-short Echo-time MR Angiography Combined with a Subtraction Method to Assess Intracranial Aneurysms Treated with a Flow-diverter Device.

Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine(2023)

引用 4|浏览4
暂无评分
摘要
A flow-diverter (FD) device is a well-established tool for the treatment of unruptured intracranial aneurysms. Time-of-flight (TOF) MR angiography (MRA) is widely used for postoperative assessment after the treatment with FD; however, it cannot fully visualize intra-aneurysmal and intrastent flow signals due to the magnetic susceptibility from the FD. Recently, the utility of MRA with ultra-short TE (UTE) sequence and arterial spin labeling technique in assessing the therapeutic efficacy of intracranial aneurysms treated with metallic devices has been reported, but long image acquisition time is one of the drawbacks of this method. Herein, we introduce a novel UTE MRA using the subtraction method that enables the reduction in susceptibility artifacts with a short image acquisition time.
更多
查看译文
关键词
flow-diverter,intracranial aneurysm,magnetic resonance angiography,ultra-short echo time