Impact of power supply fluctuation and part load operation on the efficiency of alkaline water electrolysis

Journal of Power Sources(2023)

引用 3|浏览5
暂无评分
摘要
Contrary to traditional electrolysers which operate continuously at their nominal load, future alkaline electro-lysers need to be able to operate over a wide load range due to the variability of renewable electricity supply. We have investigated how the residual ripples from thyristor-based power supplies are influenced by the operating load of the system, and how these ripples affect the efficiency of alkaline electrolysers. For this, a simulation tool was developed which combines a six-pulse bridge thyristor rectifier model with closed-loop current control and semi-empirical electrolysis models. The electrolysis models can simulate the potential response to both direct and high amplitude alternating currents for lab-scale and industrial electrolysers. The electrolysis model of the lab-scale electrolyser was validated with experiments with a square wave current input. The models show that without filters the ripples result in a total system efficiency loss of 1.2-2.5% at full load and of 5.6-10.6% at a part load of 20% depending on the type of electrolyser. The implementation of an optimized L-filter suppresses residual ripples and reduces the efficiency losses to 0.5%-0.8% at full load and to 0.8-1.2% at the minimum load.
更多
查看译文
关键词
Alkaline water electrolysis,Power Conversion,Dynamic modelling,Capacitance