Effect of spray operation conditions on Nox emission control in a power station

CHEMICAL ENGINEERING RESEARCH & DESIGN(2023)

引用 0|浏览2
暂无评分
摘要
Adequately mixing of reactants is an important factor for efficient deNOx process in power station NOx emission control system. In this study, an experimental validated CFD simulation is conducted to investigate the effect of spray operation conditions on the mixing uniformity of reactant ammonia vapor in deNOx process occurring in a power station's furnace. According to the CFD simulation results, it is found that spray mo-mentum ratio, initial droplet size and initial ammonia concentration all affect the mixing uniformity of ammonia vapor. Overall, a larger spray momentum ratio, larger initial droplet size and lower ammonia concentration contributes positively to the mixing uni-formity. By comparing the same spray momentum ratio but different nozzle inlet velocity and furnace inlet velocity, it is found that the impact of spray momentum ratio mainly comes from furnace inlet velocity not nozzle inlet velocity. In addition, gravity should not be neglected. In the end, the method described in this study could provide a systematic way to study the effects of nozzle operation conditions on deNOx process.(c) 2023 The Authors. Published by Elsevier Ltd on behalf of Institution of Chemical Engineers. This is an open access article under the CC BY license (http://creative-commons.org/licenses/by/4.0/).
更多
查看译文
关键词
NOx emission,Power station,Ammonia,Spray,CFD
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要