Higher plasma levels of thymosin-α1 are associated with a lower waning of humoral response after COVID-19 vaccination: an eight months follow-up study in a nursing home

Immunity & ageing : I & A(2023)

引用 1|浏览13
暂无评分
摘要
Background Older people achieve lower levels of antibody titers than younger populations after Covid-19 vaccination and show a marked waning humoral immunity over time, likely due to the senescence of the immune system. Nevertheless, age-related predictive factors of the waning humoral immune response to the vaccine have been scarcely explored. In a cohort of residents and healthcare workers from a nursing home that had received two doses of the BNT162b2 vaccine, we measured specific anti-S antibodies one (T1), four (T4), and eight (T8) months after receiving the second dose. Thymic-related functional markers, including thymic output, relative telomere length, and plasma thymosin-α1 levels, as well as immune cellular subsets, and biochemical and inflammatory biomarkers, were determined at T1, and tested for their associations with the magnitude of the vaccine response (T1) and the durability of such response both, at the short- (T1-T4) and the long-term (T1-T8). We aimed to identify age-related factors potentially associated with the magnitude and persistence of specific anti-S immunoglobulin G (IgG)-antibodies after COVID-19 vaccination in older people. Results Participants (100% men, n = 98), were subdivided into three groups: young (< 50 years-old), middle-age (50–65 years-old), and older (≥65 years-old). Older participants achieved lower antibody titers at T1 and experienced higher decreases in both the short- and long-term. In the entire cohort, while the magnitude of the initial response was mainly associated with the levels of homocysteine [β (95% CI); − 0.155 (− 0.241 to − 0.068); p = 0.001], the durability of such response at both, the short-term and the long-term were predicted by the levels of thymosin-α1 [− 0.168 (− 0.305 to − 0.031); p = 0.017, and − 0.123 (− 0.212 to − 0.034); p = 0.008, respectively]. Conclusions Higher plasma levels of thymosin-α1 were associated with a lower waning of anti-S IgG antibodies along the time. Our results suggest that plasma levels of thymosin-α1 could be used as a biomarker for predicting the durability of the responses after COVID-19 vaccination, possibly allowing to personalize the administration of vaccine boosters.
更多
查看译文
关键词
BNT162b2 vaccine,Magnitude and persistence of humoral response,Antibody waning,Nursing home,Thymic-function,Sj/β-TRECs ratio,RTL,Thymosin-α1,Immunesenescence,Inflammaging
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要