摘要
Synthetic mesh is now used for inguinal hernia repair in most cases. It is well known that the indwelling mesh contracts after placement in the body, regardless of the material. The aim of this study was to develop a method for indirect measurement of the mesh area postoperatively that allows for easy comparison with the condition of the mesh immediately after surgery. X-ray-impermeable tackers were used to fix the mesh, and changes of the indwelling mesh after surgery were measured indirectly using two mesh materials. This study involved 26 patients who underwent inguinal hernia repair with a polypropylene or polyester mesh (13 patients each). Polypropylene showed a stronger tendency to shrink, but there was no significant difference between the materials. For both materials, some patients showed relatively strong shrinkage and others showed relatively weak shrinkage. The group with the strong shrinkage had significantly higher body mass index. The results of the present study showed that mesh surly shrinked over time and there was no adverse effect of mesh shrinkage on the patients outcomes in this population. Mesh would shrink over time regardless of the sort of mesh but it did not affect the patients outcomes.