Ascertaining the optimal myoelectric signal recording duration for pattern recognition based prostheses control.

Frontiers in neuroscience(2023)

引用 0|浏览1
暂无评分
摘要
The between-SRD strategy results which is a reflection of the practical scenario showed that an SRD greater than 5 s but less than or equal to 10 s (>5 and < = 10 s) would be required to achieve decent average finger gesture decoding accuracy for all feature-classifier combinations. Notably, lengthier SRD would incur more acquisition and implementation time and vice-versa. In inclusion, the study's findings provide insight and guidance into selecting appropriate SRD that would aid inadequate characterization of multiple classes of limb motion tasks in PR-based control schemes for multifunctional prostheses.
更多
查看译文
关键词
electromyogram (EMG),finger gestures,pattern recognition (PR),prostheses,signal recording duration (SRD)