Purpose(123)I-metaiodobenzylguanidine (MIBG) cardiac scintigraphy was a useful imaging modality for the diagnosis of Parkinson's disease, but its diagnostic performances were variably reported. This retrospective study compared the diagnostic performances and investigated the optimal imaging protocol of I-123-MIBG cardiac scintigraphy at various imaging time points in patients suspected of Parkinson's disease in clinical practice.MethodsIn patients suspected of Parkinson's disease, clinical records, autonomic function tests, and I-123-MIBG cardiac scintigraphy were retrospectively reviewed. Semi-quantitative parameters such as heart-to-mediastinum ratio (HMR) and washout rate (WR) were calculated and compared at 15 min, 1 h, 2 h, 3 h, and 4 h post-injection (p.i.). of I-123-MIBG cardiac scintigraphy. Group A consisted of Parkinson's disease (PD), Parkinson's disease dementia (PDD), and dementia with Lewy body (DLB), and group B consisted of non-Parkinson's diseases such as multiple system atrophy (MSA), progressive supranuclear palsy (PSP), drug-induced parkinsonism (DIP), essential tremor (ET), Parkinson-plus syndrome (PPS), and unspecified secondary parkinsonism (NA). The diagnostic performances of HMR and WR were compared for differentiation of group A from group B, and their clinical usefulness and optimal imaging time points were explored.ResultsSeventy-eight patients were included in group A (67 PD, 7 PDD, 4 DLB), and 18 patients were included in group B (5 MSA, 3 PSP, 2 DIP, 2 ET, 1 PPS, and 1 NA). Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value of HMR and WR were maximized at 4 h p.i., (82.1%, 85.7%, 82.6%, 97.0%, and 46.2%; cutoff threshold < 1.717; area under curve 0.8086) and at the time interval between 1 and 4 h p.i. (65.4%, 85.7%, 68.5%, 96.2%, and 30.8%; cutoff threshold > 24.1%; area under curve 0.8246), respectively, and PPVs of both HMR and WR persistently showed greater than 92.7% at earlier time points and shorter time intervals.ConclusionThis study reassured that 4-h-delayed imaging is recommended for the best diagnostic performances in I-123-MIBG cardiac scintigraphy. Although it showed suboptimal diagnostic performances to differentiate PD, PDD, and DLB from non-Parkinson's diseases, it can be useful as an auxiliary measure for the differential diagnosis in usual clinical practice.
更多
查看译文
关键词
I-123-MIBG cardiac scintigraphy,Heart-to-mediastinum ratio,Washout rate,Parkinson's disease,Dementia with Lewy body,Atypical Parkinson syndrome
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要