An evaluation of the clinical efficacy of the application of 28mm cryoballoon for linear ablation of left atrial apex combined with enlarged pulmonary vein vestibule ablation for persistent atrial fibrillation

Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese(2023)

引用 0|浏览2
暂无评分
摘要
Objective: to retrospectively investigate the efficacy and safety of the application of 28 mm cryoballoon for pulmonary vein electrical isolation (PVI) combined with top left atrial linear ablation and pulmonary vein vestibular expansion ablation for persistent atrial fibrillation.Methods: From July 2016 to December 2020, 413 patients diagnosed with persistent atrial fibrillation were evaluated, including 230 (55.7%) in the PVI group (PVI only) and 183 (44.3%) in the PVIPLUS group (PVI plus ablation of the left atrial apex and pulmonary vein vestibule). The safety and efficacy of the two groups were retrospectively analyzed.Results: The AF/AT/AFL-free survival rates at 6, 12, 18, 24 and 30 months after procedure was 86.6%, 72.6%, 70.0%, 61.1% and 56.3% in the PVI group and 94.5%, 87.0%, 84.1%, 75.0% and 67.9% in the PVIPLUS group, respectively. At 30 months after procedure, the AF/AT/AFL-free survival rate was significantly higher in the PVIPLUS group than in the PVI group (P 1/4 0.036; HR:0.63; 95% CI:0.42 to 0.95).Conclusion: The application of 28-mm cryoballoon for pulmonary vein electrical isolation combined with linear ablation of the left atrial apex and expanded ablation of the pulmonary vein vestibule improves the outcome of persistent atrial fibrillation.& COPY; 2023 Hellenic Society of Cardiology. Publishing services by Elsevier B.V.This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
更多
查看译文
关键词
persistent atrial fibrillation,28-mm cryoablation,pulmonary vein isolation,segmental isolation,pulmonary vein vestibule expansion,ablation,left atrial apex linear ablation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要