Sewage in wastewater treatment plants (WWTPs) can produce fugitive bioaerosols that pose a health risk to employees and residents. This study aimed to fugitive bioaerosols from two WWTPs with anaerobic-anoxic-oxic (AAO) processes, and bioaerosols control measures were proposed based on the results of these studies. It was found that the bioaerosols were mainly composed of microorganisms from dominant genera such as Romboutsia, Rubellimicrobium, Sphingomonas, Acidea, Cryptotrichosporon and water-soluble ions dominated by SO42-. Moreover, total suspended particulate (TSP), relative humidity (RH), wind speed (WS), Ca2+, NH4+, Na+, Cl-, NO3-, and K+ had positive effects on most dominant genera, while temperature (T) and SO42- had negative effects on most dominant genera. The source analysis showed that the bioaerosols in the indoor treatment facility's fine screen room and sludge dewatering plant mainly originated from sewage or sludge, and those in the aeration tank of the outdoor treatment facility mainly originated from the background air of WWTPs . By combining the characteristics of bioaerosols and the results of source analysis, targeted control measures were proposed from three aspects: source reduction of bioaerosol fugitives, control of bioaerosol propagation, and collection and treatment systems. This study provides the theoretical basis and ideas for controlling bioaerosols in WWTPs with AAO processes.