Agreement between a 3D camera system and an inertial measurement unit for assessing the range of motion, head repositioning accuracy and quality of movement during neck and head movements

EUROPEAN JOURNAL OF PHYSIOTHERAPY(2024)

引用 4|浏览0
暂无评分
摘要
Purpose: Altered head range of motion (RoM) and head repositioning accuracy (HRA) are commonly reported in neck pain. However, the quality of motion (QoM) is currently not easy to assess clinically. This study investigated the agreement of head rotation recordings using a 3D camera system compared to a commercially available inertial measurement unit (MOTI).Materials and methods: Thirty participants, mean age 26.5 years old (SD 4.4), partook in this study. Participants wore a Headband with MOTI and markers for 3D motion capture analysis during head rotations. The two systems recorded active head RoM in rotation, HRA, and QoM. Agreement of RoM, HRA and QoM data was compared between the two systems using Interclass correlation coefficients (ICC; 2.1) and Bland-Altman plots.Results: Good to excellent agreement between the two systems was seen for RoM (ICC: 0.998), HRA (0.75-0.88) and QoM (ICC: 0.911-0.913). The Bland-Altman plots revealed a systemic offset where the MOTI device measured higher values for RoM (mean bias: -0.56 +/- 0.65 degrees), HRA (mean bias: 0.48 +/- 0.76 degrees) and QoM (mean bias: -16.9 +/- 51.6 A.U.).Conclusion: The present study found that the MOTI device can accurately measure RoM, HRA and QoM during head rotation. MOTI may be preferred over a 3D camera system for clinical use.
更多
查看译文
关键词
Range of motion,motion capture,kinematics,head movements,neck pain
AI 理解论文