Thermal Runaway Vent Gases from High-Capacity Energy Storage LiFePO4 Lithium Iron

ENERGIES(2023)

引用 2|浏览14
暂无评分
摘要
Lithium batteries are being utilized more widely, increasing the focus on their thermal safety, which is primarily brought on by their thermal runaway. This paper's focus is the energy storage power station's 50 Ah lithium iron phosphate battery. An in situ eruption study was conducted in an inert environment, while a thermal runaway experiment was conducted utilizing sealed pressure containers and an external heating triggering mechanism. Both the amount of gas release and the battery's maximum temperature were discovered. Using gas chromatography, the gas emission from the battery was examined. Its principal constituents included CO, H-2, CO2, CH4, C2H4, and so on. Moreover, the experiment discovered a second eruption of lithium iron phosphate, and the stage of its eruption was separated by the pressure signal of the sealed experimental chamber, giving a theoretical foundation and technological backing for the thermal catastrophe safety of lithium batteries.
更多
查看译文
关键词
thermal runaway vent gases,high-capacity
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要