谷歌浏览器插件
订阅小程序
在清言上使用

Abstract No. 248 Accuracy of a Cone-Beam CT-Based Liver-Directed Therapy Planning Software for Perfused Parenchyma Prediction

O. Chevallier,H. Yarmohammadi, K. Zhao, L. Kiely,V. Sotirchos,F. Ridouani,E. Alexander, S. Solomon,M. Silk

Journal of vascular and interventional radiology(2023)

引用 0|浏览7
暂无评分
摘要
Accurate intraprocedural assessment of injected liver volume and distribution can help guide safe and effective hepatic intraarterial therapy. The purpose of this study is to assess the accuracy of a cone-beam CT (CBCT)-based liver-directed therapy planning software to predict volume and distribution of the targeted perfused liver parenchyma (Liver ASSIST Virtual Parenchyma, GE Healthcare, Chicago, IL). This IRB-approved retrospective study included patients with CBCT (whole liver or lobar) and at least one selective CT-Angiography (CTA) (sub-segmental to lobar) obtained during hepatic angiography in a hybrid CT-angio suite from 2019 to 2022. Quality of CTA and CBCT images were evaluated by 3 reviewers. Studies were excluded if there was poor enhancement, artifact, or targeted liver truncation by the CBCT’s field of view. Software automatically generated a predicted targeted liver parenchyma (pTLP) based on the CBCT, which was then manually adjusted (cTLP) using tools integrated in the software. The true targeted liver parenchyma (TLP) was defined from manual segmentation of the selective CTA. Software accuracy for volume was assessed by comparing the pTLP/cTLP to the matched TLP, and analyzed with relative error and linear regression analysis. Spatial overlap accuracy for parenchymal distribution between pTLP/cTLP and TLP was assessed by the Dice similarity coefficient (DSC). Nineteen patients met the inclusion criteria (26 CTA matched with a CBCT). CTA were lobar, sectoral, segmental, and subsegmental; 5 (19%), 8 (31%), 11 (42%), and 2 (8%) respectively. The median TLP was 323 mL [IQR 145;534]. pTLP and cTLP were well correlated with TLP (r = 0.98, P< 0.001; and r = 0.99, P< 0.001; respectively). For pTLP and cTLP, median relative errors in volume prediction were 13% [IQR 3;21%] and 9% [IQR 3;18%] respectively. Median DSC were 0.79 [IQR 0.71;0.82] and 0.83 [IQR 0.76;0.86] respectively. This software provides an accurate prediction of perfused liver parenchyma from a virtual point of treatment placed on a proximal CBCT. Investigation of its intraprocedural value for intra-arterial liver-directed therapies planning is warranted.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要