Development of a 127Xe calibration source for nEXO

B.G. Lenardo, C.A. Hardy, R.H.M. Tsang,J.C. Nzobadila Ondze, A. Piepke, S. Triambak, A. Jamil, G. Adhikari,S. Al Kharusi, E. Angelico, I.J. Arnquist, V. Belov, E.P. Bernard, A. Bhat, T. Bhatta, A. Bolotnikov,P.A. Breur, J.P. Brodsky, E. Brown, T. Brunner, E. Caden,G.F. Cao, L. Cao, B. Chana, S.A. Charlebois, D. Chernyak, M. Chiu, J.R. Cohen, R. Collister, J. Dalmasson, T. Daniels, L. Darroch, R. DeVoe,M.L. di Vacri, Y.Y. Ding, M.J. Dolinski, J. Echevers, B. Eckert, M. Elbeltagi, L. Fabris, D. Fairbank, W. Fairbank, J. Farine, Y.S. Fu, G. Gallina,P. Gautam, G. Giacomini, W. Gillis, C. Gingras, R. Gornea, G. Gratta, K. Harouaka, M. Heffner, E. Hein, J. Hößl, A. House, A. Iverson, X.S. Jiang, A. Karelin, L.J. Kaufman,R. Krücken, A. Kuchenkov, K.S. Kumar, A. Larson, K.G. Leach,D.S. Leonard,G. Li, S. Li,Z. Li, C. Licciardi, R. Lindsay, R. MacLellan, J. Masbou, K. McMichael, M. Medina Peregrina, B. Mong,D.C. Moore, K. Murray, J. Nattress, C.R. Natzke, X.E. Ngwadla, K. Ni, Z. Ning, J.L. Orrell, G.S. Ortega, I. Ostrovskiy, C.T. Overman, A. Perna, T. Pinto Franco, A. Pocar, J.F. Pratte, N. Priel, E. Raguzin, G.J. Ramonnye, H. Rasiwala, K. Raymond, G. Richardson, M. Richman, J. Ringuette,P.C. Rowson, R. Saldanha, S. Sangiorgio, X. Shang, A.K. Soma, F. Spadoni, V. Stekhanov, X.L. Sun, S. Thibado, A. Tidball, J. Todd, T. Totev, O.A. Tyuka, F. Vachon, V. Veeraraghavan, S. Viel, K. Wamba, Y. Wang, Q. Wang, W. Wei, L.J. Wen, U. Wichoski, S. Wilde, W.H. Wu, W. Yan, L. Yang, O. Zeldovich, J. Zhao, T. Ziegler

Journal of Instrumentation(2022)

引用 0|浏览6
暂无评分
摘要
Abstract We study a possible calibration technique for the nEXO experiment using a 127Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127Xe and its small Q-value compared to that of 136Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要