A computational discharge model for sphere-plane long air gap under switching impulse voltage

AIP ADVANCES(2023)

引用 0|浏览2
暂无评分
摘要
There are lots of sphere-plane air gaps in valve halls in extra-high-voltage and ultra-high-voltage converter stations. Accurate prediction for discharge characteristics of sphere-plane gaps is of great significance for the selection of shielding structure and determining the dielectric strength of the valve hall. In this paper, based on the physical process of corona inception and continuous leader inception, a computational model for calculating the discharge voltage of a sphere-plane air gap under positive switching impulse voltage is proposed, and the leader characteristics and discharge voltage are analyzed. Then, the switching impulse discharge test of the sphere-plane gap with 0.15, 2, and 0.3 m radius spherical electrodes is carried out to verify the correctness of the model. The results show that the discharge voltage calculated by the proposed method is consistent with the test results, and the error is within 7.3%. The leader inception voltage and inception time increase with the increasing spherical electrode radius at the same gap distance, and an identical spherical electrode require higher leader inception voltage and faster leader inception time with the increasing gap distance.
更多
查看译文
关键词
computational discharge model,impulse voltage,long air gap
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要