Detection of Cd2+ based on Nano-Fe3O4/MoS2/Nafion/GCE sensor

ANALYTICAL SCIENCES(2023)

引用 0|浏览0
暂无评分
摘要
It is necessary to detect cadmium ions in seawater with high sensitivity because the pollution of cadmium ions seriously endangers the health and life of human beings. Nano-Fe3O4/MoS2/Nafion modified glassy carbon electrode was prepared by a drop coating method. The electrocatalytic properties of Nano-Fe3O4/MoS2/Nafion were measured by Cyclic Voltammetry (CV). Differential Pulse Voltammetry (DPV) was used to study the stripping Voltammetry response of the modified electrode to Cd2+. The optimal conditions were determined: In 0.1 mol/L HAc-NaAc solution, the solution pH was 4.2, the deposition potential was − 1.0 V, and the deposition time was 720 s, the membrane thickness was 8 μL. Under the optimum condition, the linear relation of Cd2+ concentration was found in the range of 5–300 μg/L, and the detection limit was 0.053 μg/L. The recovery of Cd2+ in seawater ranged from 99.2 to 102.9