Accuracy of Ultrasound Imaging for Etiology of New-Onset Painless Jaundice.

Journal of computer assisted tomography(2023)

引用 0|浏览3
暂无评分
摘要
A US-first strategy in the setting of new-onset painless jaundice is accurate only 78% of the time. In practice, US was almost never a stand-alone imaging examination in patients presenting to the emergency department or inpatient setting with new-onset painless jaundice, no matter the suspected diagnosis based on clinical and laboratory grounds or on the US findings themselves. However, for milder elevations of unconjugated bilirubin (suspicious for Gilbert disease) in the outpatient setting, a US demonstrating lack of biliary dilatation was often a definitive study for exclusion of pathology.