Sulopenem Disk Development, Quality Control Range, and MIC to Disk Result Correlation for Enterobacterales Isolates.

Journal of clinical microbiology(2023)

引用 0|浏览0
暂无评分
摘要
Sulopenem disk masses of 2, 5, 10, and 20 μg were evaluated by susceptibility testing isolates by broth microdilution and disk diffusion. A 2-μg disk was chosen, and error-rate bounding analysis in accordance with Clinical and Laboratory Standards Institute (CLSI) guideline M23 was conducted using a proposed sulopenem susceptible/intermediate/resistant (S/I/R) interpretive criterion of ≤0.5/1/≥2 μg/mL. Among the evaluated ( = 2,856), very few interpretive errors were observed (no very major errors and only one major error). An eight-laboratory quality control (QC) study was performed using the 2-μg disk, and 99.0% (470/475) of results were within a 7-mm range of 24 to 30 mm. Results were similar by disk lot and media, and no outlier sites were observed. A sulopenem 2-μg disk QC range for Escherichia coli 29522 of 24 to 30 mm was established by the CLSI. A 2-μg sulopenem disk performs accurately and reproducibly for testing of .
更多
查看译文
关键词
sulopenem disk development,disk result correlation