Agreement of cardiac output measurements by esophageal Doppler and transesophageal echocardiography with intermittent pulmonary artery thermodilution during pharmacologic manipulation of hemodynamics in anesthetized dogs.

American journal of veterinary research(2023)

引用 2|浏览5
暂无评分
摘要
For minimally invasive CO monitoring, TEE may provide more favorable performance than EDM in clinical settings; however, EDM-derived indexes yield valuable hemodynamic information that reliably follows trends in CO, thus supporting critical decision-making in canine patients.
更多
查看译文
关键词
intermittent pulmonary artery thermodilution,cardiac output measurements,transesophageal echocardiography,anesthetized dogs,pulmonary artery