BackgroundTo explore whether a long-distance optical image workbench (LOIW) can replace traditional near-distance reading and has beneficial influences on accommodation and choroidal parameters.MethodsThis self-control study included two sessions. In session 1, an open-field autorefractor measured sustained accommodative response and pupil diameter when participants viewed virtual images from 3.42 m away through LOIW with + 0.50 D over-correction lenses (3.42 m/+0.50 D), LOIW with full-correction lenses (3.42 m/FC), or the visual target at a given distance of 0.33 m with + 0.50 D over-correction lenses (0.33 m/+0.50 D), with full-correction lenses (0.33 m/FC). In session 2, swept-source optical coherence tomography angiography assessed subfoveal choroidal thickness (SFChT), choroidal volume (CV), and choriocapillaris flow void percentage (FV%) at baseline and before and after reading via LOIW with + 0.50 D over-correction lenses (Far/+0.50 D) or in habitual near distance with full-correction (Near/FC) for a sustained 30-min period.ResultsThirty-five myopic (mean spherical equivalent refraction: -1.11 & PLUSMN; 0.78 D) children (median [range] age: 8.36 [8-10] years) were analysed. Children viewing virtual images in 3.42 m/+0.50 D exhibited mild-degree accommodative leads (-0.54 & PLUSMN; 0.17 D), much smaller pupil diameter (3.39 & PLUSMN; 0.63 mm) and microfluctuations (0.13 & PLUSMN; 0.04 D); accommodative lags (0.88 & PLUSMN; 0.04 D), larger pupil diameter (5.05 & PLUSMN; 0.75 mm) and microfluctuations (0.88 & PLUSMN; 0.16 D) were observed in 0.33 m/+0.50 D, and the microfluctuations were unstable (F = 2.185, p = 0.038). Compared with baseline data, SFChT, CV, and FV% changed by 13.40 & PLUSMN; 4.71 & mu;m, 0.26 & PLUSMN; 0.21 mm(3), and - 0.14%& PLUSMN;3.66% in Far/+0.50 D, respectively, while changes under Near/FC were - 10.19 & PLUSMN; 7.48 & mu;m, -0.15 & PLUSMN; 0.22 mm(3) and 1.95%& PLUSMN;2.92%, respectively. All changes differed significantly between these two conditions (all p < 0.001).ConclusionThe long-distance working mode may exert beneficial effects on accommodative and choroidal parameters in myopic children compared with traditional near work.
更多
查看译文
关键词
Accommodation,children,choroid,myopia,near work
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要