Pd23-10 real-time mri reveals a change in prostatic urethral angle during voiding

C. A. Johnson, Juan Pablo Gonzalez-Pereira,Labib Shahid, Maxwell Kounga,Shane A. Wells,Wade Bushman,Alejandro Roldán‐Alzate

The Journal of Urology(2023)

引用 0|浏览2
暂无评分
摘要
You have accessJournal of UrologyCME1 Apr 2023PD23-10 REAL-TIME MRI REVEALS A CHANGE IN PROSTATIC URETHRAL ANGLE DURING VOIDING Cody Johnson, Juan P. Gonzalez-Pereira, Labib Shahid, Maxwell Kounga, Shane Wells, Wade Bushman, and Alejandro Roldan-Alzate Cody JohnsonCody Johnson More articles by this author , Juan P. Gonzalez-PereiraJuan P. Gonzalez-Pereira More articles by this author , Labib ShahidLabib Shahid More articles by this author , Maxwell KoungaMaxwell Kounga More articles by this author , Shane WellsShane Wells More articles by this author , Wade BushmanWade Bushman More articles by this author , and Alejandro Roldan-AlzateAlejandro Roldan-Alzate More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003296.10AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Dynamic changes in urethral anatomy during voiding have never been quantitatively assessed. We used real-time magnetic resonance imaging (MRI) to obtain dynamic, high-fidelity 3D images of the lower urinary tract during voiding. These were then used to create accurate real-time urethral reconstructions throughput the voiding event coupled with determinations of urine flow, pressure and wall shear stress by computational fluid dynamics (CFD). METHODS: MRI scans were performed on a healthy young man using a clinical 3T scanner according to an IRB-approved protocol to acquire a 3D image every 3.7 s during voiding. 3D models of the urethral lumen were created using MIMICS (Materialise, Leuven, Belgium). RESULTS: Diameters of the internal and external urethral sphincter (IUS, EUS) and prostatic urethral angle (PUA) were obtained throughout voiding. CFD, using computational software to model and simulate fluid behavior under specified constraints of geometry and flow, was used to determine wall shear stress (WSS), pressures and fluid velocities along the length of the urethra during maximum flow (Figure 1). IUS diameter remains unchanged throughout voiding whereas EUS diameter correlates positively with urine flow rate (data not shown here). Most notably, we noted a striking change in PUA during voiding. PUA becomes less acute as flow increases, being straightest at peak flow rate (Figure 2). CONCLUSIONS: Real-time MRI can be used to define the biomechanics of the urethra during voiding and reveals – for the first time – a change in prostatic urethral angle during voiding that correlates with urinary flow rate. Source of Funding: NIH: R01 DK126850-01 © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e675 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.MetricsAuthor Information Cody Johnson More articles by this author Juan P. Gonzalez-Pereira More articles by this author Labib Shahid More articles by this author Maxwell Kounga More articles by this author Shane Wells More articles by this author Wade Bushman More articles by this author Alejandro Roldan-Alzate More articles by this author Expand All Advertisement PDF downloadLoading ...
更多
查看译文
关键词
urethral angle,prostatic,mri,real-time
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要