Mp26-20 randomized trial of single-use versus reusable cystoscope for ureteral stent removal

The Journal of Urology(2023)

引用 0|浏览2
暂无评分
摘要
You have accessJournal of UrologyCME1 Apr 2023MP26-20 RANDOMIZED TRIAL OF SINGLE-USE VERSUS REUSABLE CYSTOSCOPE FOR URETERAL STENT REMOVAL Brett Johnson, Jay Raman, Best Sara, and Yair Lotan Brett JohnsonBrett Johnson More articles by this author , Jay RamanJay Raman More articles by this author , Best SaraBest Sara More articles by this author , and Yair LotanYair Lotan More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003254.20AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: Reusable cystoscopes are associated with risks of cross-contamination, need for chemical reprocessing, mechanical breakdown, manpower for cleaning and maintenance costs. A sterile, single use cystoscope may reduce or eliminate the source of these infections, while also decreasing exposure to reprocessing chemical agents. This multicenter, prospective randomized trial compared single-use vs. reusable endoscope for removal of ureteral stents. METHODS: The evaluation of a single-use cystoscope (Ambu A/S) was completed in a prospective, randomized, dual-arm post-market clinical trial to directly compare its performance to standard of care (SOC) flexible reusable cystoscopes in the removal of ureteral stents in an outpatient setting. 102 patients were evaluated from baseline through day 10 post-procedure at three investigative sites. The primary endpoint was the success rate of the stent removal procedures, delineated by single-use or reusable cystoscope. Secondary endpoints included time from preparation to disposal or reprocessing preparation, urologic adverse events 0-10 days, and a post-procedure clinician satisfaction survey. RESULTS: There were 102 subjects, randomized 1:1 between the single-use scope and SOC reusable scope. The successful stent removal rate was 51/51 for SOC group and 50/51 for single-use group (p=1.00). One patient required the conversion to a reusable scope due to a grasper passage issue with the index scope. There was no statistical difference in the time from scope insertion to procedure completion between the study arms. Median time from prep for the procedure to disposal/prep for reprocessing was 611 sec. for the single-use and 1105 sec. for the reusable (p=0.00). Reprocessing time was not evaluated in study. The 5-point survey demonstrated no difference in clinician satisfaction between both arms across all parameters addressed, as seen in the Clinician Satisfaction Table. There was no difference in adverse events between arms and no device causal attribution for any adverse events reports. One serious adverse event required hospitalization for infection in the SOC arm. CONCLUSIONS: The RCT of single-use cystoscopes vs. reusables showed comparable device success with significant time savings for single-use and equal clinician satisfaction. Source of Funding: Ambu USA sponsored this trial. © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e361 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.MetricsAuthor Information Brett Johnson More articles by this author Jay Raman More articles by this author Best Sara More articles by this author Yair Lotan More articles by this author Expand All Advertisement PDF downloadLoading ...
更多
查看译文
关键词
versus reusable cystoscope,stent,randomized trial,single-use
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要