Individualization of Atrial Tachycardia Models for Clinical Applications: Performance of Fiber-Independent Model

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING(2024)

引用 0|浏览14
暂无评分
摘要
One of the challenges in the development of patient-specific models of cardiac arrhythmias for clinical applications has been accounting for myocardial fiber organization. The fiber varies significantly from heart to heart, but cannot be directly measured in live tissue. The goal of this paper is to evaluate in-silico the accuracy of left atrium activation maps produced by a fiber-independent (isotropic) model with tuned diffusion coefficients, compares to a model incorporating myocardial fibers with the same geometry. For this study we utilize publicly available DT-MRI data from 7 ex-vivo hearts. The comparison is carried out in 51 cases of focal and rotor arrhythmias located in different regions of the atria. On average, the local activation time accuracy is 96% for focal and 93% for rotor arrhythmias. Given its reasonably good performance and the availability of readily accessible data for model tuning in cardiac ablation procedures, the fiber-independent model could be a promising tool for clinical applications.
更多
查看译文
关键词
Arrhythmia,Mathematical models,Rotors,Heart,Modeling,Computational modeling,Data models,cardiac electric propagation,fiber-independent heart model,flutter,focal arrhythmia,left atrium,patient-specific,rotor arrhythmia,tachycardia