High Myopia Normative Database of Peripapillary Retinal Nerve Fiber Layer Thickness to Detect Myopic Glaucoma in a Chinese Population

OPHTHALMOLOGY(2023)

引用 0|浏览5
暂无评分
摘要
Purpose: To develop and validate the performance of a high myopia (HM)-specific normative database of peripapillary retinal nerve fiber layer (pRNFL) thickness in differentiating HM from highly myopic glaucoma (HMG).Design: Cross-sectional multicenter study.Participants: A total of 1367 Chinese participants (2325 eyes) with nonpathologic HM or HMG were included from 4 centers. After quality control, 1108 eyes from 694 participants with HM were included in the normative database; 459 eyes from 408 participants (323 eyes with HM and 136 eyes with HMG) and 322 eyes from 197 participants (131 eyes with HM and 191 eyes with HMG) were included in the internal and external validation sets, respectively. Only HMG eyes with an intraocular pressure > 21 mmHg were included.Methods: The pRNFL thickness was measured with swept-source (SS) OCT. Four strategies of pRNFL-specified values were examined, including global and quadrantic pRNFL thickness below the lowest fifth or the lowest first percentile of the normative database.Main outcomes measures: The accuracy, sensitivity, and specificity of the HM-specific normative database for detecting HMG.Results: Setting the fifth percentile of the global pRNFL thickness as the threshold, using the HM-specific normative database, we achieved an accuracy of 0.93 (95% confidence interval [CI], 0.90-0.95) and 0.85 (95% CI, 0.81-0.89), and, using the first percentile as the threshold, we acheived an accuracy of 0.85 (95% CI, 0.81-0.88) and 0.70 (95% CI, 0.65-0.75) in detecting HMG in the internal and external validation sets, respectively. The fifth percentile of the global pRNFL thickness achieved high sensitivities of 0.75 (95% CI, 0.67-0.82) and 0.75 (95% CI, 0.68-0.81) and specificities of 1.00 (95% CI, 0.99-1.00) and 1.00 (95% CI, 0.97-1.00) in the internal and external validation datasets, respectively. Compared with the built-in database of the OCT device, the HM-specific normative database showed a higher sensitivity and specificity than the corresponding pRNFL thickness below the fifth or first percentile (P < 0.001 for all).Conclusions: The HM-specific normative database is more capable of detecting HMG eyes than the SS OCT built-in database, which may be an effective tool for differential diagnosis between HMG and HM.
更多
查看译文
关键词
Glaucoma,High myopia,Normative database,OCT,Retinal nervefiber layer
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要