Thyroid segmentation using perithyroidal halo layer on 99mTc-pertechnetate thyroid SPECT/CT: An easy and reliable method for accurate quantification of thyroid activity

Hellenic journal of nuclear medicine(2023)

引用 0|浏览2
暂无评分
摘要
Objective: In previous uorine-18-uorodeoxyglucose positron emission tomography/computed tomography (F-18-FDG PET/CT) studies, tumor segmentation using peritumoral halo layer (PHL; SegPHL) was shown to be reliable and accurate segmentation method in various malignant tumors. We found that the halo layer also was observed on the Tc-99m pertechnetate ((TcO4)-Tc-99m) thyroid single photon emission computed tomography (SPECT)/CT. In the present study, we attempted to apply thyroid segmentation using the peri-thyroidal halo layer (PTHL; SegPTHL) on (TcO4)-Tc-99m thyroid SPECT/CT and compared SegPTHL with CT-based thyroid segmentation (SegCT). Subjects and Methods: A total of 33 patients (19 females, 14 males; mean age, 46.91 +/- 15.7 years old) were enrolled in this study. For SegCT, three-dimensional volume of interest (VOI) of the thyroid was generated via multiple 2-dimensional regions of interest (ROI) along the thyroid margin on transaxial CT images that were manually drawn slice by slice. The PTHL was easily identi ed by an abrupt increase in layer thickness with minimal or mild distortion of the main thyroid contour, and the thyroid margin for SegPTHL was determined at the innermost portion of PTHL. An automated VOI generation for SegPTHL was performed using the Q. Volumetrix software. The correlation and reliability tests were performed between the quanti cation parameters of SegPTHL and SegCT. Results: The PTHL threshold adjusted according to maximal SUV of thyroid were similar to the results of previous SegPHL studies of FFDG PET/CT. A good correlation was observed between the thyroid volumes of SegCT and SegPTHL r = 0.725; P<0.0001), although the thyroid volume of SegPTHL was slightly larger than that of SegCT (P = 0.0017). The % thyroid uptake (TcTU), total lesion activity (TLA), and mean standardized uptake value (SUVmean) of SegPTHL correlated well with those of SegCT (r=0.9877, 0.9883, 0.9875, respectively; P< 0.0001). No signi cant error was observed between the parameters (i.e., TcTU, TLA, and SUVmean) of SegPTHL and SegCT. Conclusions: Thyroid segmentation PTHL may be a useful method for reliable quanti- cation of thyroid uptake, because the SPECT/CT parameters of SegPTHL were strongly correlated with those of SegCT, as well as the process of SegPTHL is easier and faster than that of SegCT.
更多
查看译文
关键词
Perithyroidal halo layer, SPECT/CT-Quantification, Thyroid activity, Thyroid segmentation
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要