Tibial bone defect prediction based on preoperative artefact-reduced CT imaging is superior to standard radiograph assessment

Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA(2023)

引用 0|浏览2
暂无评分
摘要
Purpose The purpose of this study was to evaluate the accuracy of preoperative CT-based Anderson Orthopaedic Research Institute (AORI)-grading and to correlate Computed tomography (CT)-based volumetric defect measurements with intraoperative AORI findings. Methods 99 patients undergoing revision total knee arthroplasty (rTKA) with preoperative CT-images were identified in an institutional revision registry. CT-image segmentation with 3D-Slicer Software was used to create 3D tibial bone defects which were then graded according to the AORI-classification. The AORI classification categorizes tibial defects into three types: Type I has healthy cortical and cancellous bone near the joint line, Type II involves metaphyseal bone loss affecting one or both condyles, and Type III indicates deficient metaphyseal bone with distal defects and potential damage to the patellar tendon and collateral ligament attachments. These 3D-CT gradings were compared to preoperative X-ray and intraoperative AORI grading. The Friedman test was used to investigate differences between AORI values of each measurement method. Volumetric 3D-bone defect measurements were used to investigate the relationship between AORI classification and volumetric defect size in the three anatomic zones of the tibia. Results Substantial agreements between preoperative 3D-CT AORI and intraoperative AORI (kappa = 0.663; P < 0.01) and fair agreements between preoperative X-ray AORI and intraoperative AORI grading (kappa = 0.304; P < 0.01) were found. Moderate correlations between volume of remaining bone and intraoperative AORI grading were found in epiphysis (r S = – 0.529; P < 0.001), metaphysis (r S = – 0.557; P < 0.001) and diaphysis (r S = – 0.421; P < 0.001). Small volumetric differences between AORI I vs. AORI II defects and relatively large differences between AORI II and AORI III defects in each zone were detected. Conclusion Tibial bone defect prediction based on preoperative 3D-CT segmentation showed a substantial agreement with intraoperative findings and is superior to standard radiograph assessment. The relatively small difference in defect volume between AORI I, IIa and IIb suggests that updated CT-based classifications might hold benefits for the planning of rTKA. Level of evidence Retrospective Cohort Study; III
更多
查看译文
关键词
3D-CT,Defect classification,AORI,Zonal fixation,Volumetric defect measurement,Revision total knee arthroplasty
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要