Use of a Flexible Tip Bougie (flextip) in the Management of the First-Attempt Failure Intubation with the C-MAC D-Blade Videolaryngoscope in the Intensive Care Unit: A Prospective, Case Series.

REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION(2024)

引用 0|浏览2
暂无评分
摘要
We describe a series of 11 cases in which we used the new flexible tip (FlexTip) bougie as a rescue device following first-attempt failure at intubation with the C-MAC D-Blade video laryngoscope in our UCI. We collected data from all intubations performed using the C-MAC D-Blade video laryngoscope over a 16-month period. Ninety six patients were included in the study: 79 (86.8%) were intubated at the first attempt; 11 (12.1%) required 2 attempts; and 1 patient required 3 attempts. The Frova Intubating Introducer was used in 1 of the 12 patients requiring more than 1 intubation attempt, and the FlexTip was used in the remaining 11. This study shows that the new FlexTip bougie is a good rescue device when the first attempt at video laryngoscope intubation fails.
更多
查看译文
关键词
Intubation,Intensive care,Airway management,Difficult intubation