Diagnostic performance of artificial intelligence for pediatric pulmonary nodule detection on chest computed tomography: comparison of simulated lower radiation doses.

Rida Salman,HaiThuy N Nguyen, Andrew C Sher,Kristina Hallam, Victor J Seghers,Marla B K Sammer

European journal of pediatrics(2023)

引用 0|浏览9
暂无评分
摘要
The combination of low dose CT and AI performance in the pediatric population has not been explored. Understanding this relationship is relevant for pediatric patients given the potential radiation risks. Here, the objective was to determine the diagnostic performance of commercially available Computer Aided Detection (CAD) for pulmonary nodules in pediatric patients at simulated lower radiation doses. Retrospective chart review of 30 sequential patients between 12-18 years old who underwent a chest CT on the Siemens SOMATOM Force from December 20, 2021, to April 12, 2022. Simulated lower doses at 75%, 50%, and 25% were reconstructed in lung kernel at 3 mm slice thickness using ReconCT and imported to Syngo CT Lung CAD software for analysis. Two pediatric radiologists reviewed the full dose CTs to determine the reference read. Two other pediatric radiologists compared the Lung CAD results at 100% dose and each simulated lower dose level to the reference on a nodule by nodule basis. The sensitivity (Sn), positive predictive value (PPV), and McNemar test were used for comparison of Lung CAD performance based on dose. As reference standard, 109 nodules were identified by the two radiologists. At 100%, and simulated 75%, 50%, and 25% doses, lung CAD detected 60, 62, 58, and 62 nodules, respectively; 28, 28, 29, and 26 were true positive (Sn = 26%, 26%, 27%, 24%), 30, 32, 27, and 34 were false positive (PPV = 48%, 47%, 52%, 43%). No statistically significance difference of Lung CAD performance at different doses was found, with p-values of 1.0, 1.0, and 0.7 at simulated 75%, 50%, and 25% doses compared to standard dose. CONCLUSION:The Lung CAD shows low sensitivity at all simulated lower doses for the detection of pulmonary nodules in this pediatric population. However, radiation dose may be reduced from standard without further compromise to the Lung CAD performance. WHAT IS KNOWN:• High diagnostic performance of Lung CAD for detection of pulmonary nodules in adults. • Several imaging techniques are applied to reduce pediatric radiation dose. WHAT IS NEW:• Low sensitivity at all simulated lower doses for the detection of pulmonary nodules in our pediatric population. • Radiation dose may be reduced from standard without further compromise to the Lung CAD performance.
更多
查看译文
关键词
Lung nodules,Artificial intelligence,CAD,Computer Aided Detection,Dose,Pediatric
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要