The Anteroposterior Positioning of Viscoelastic Cervical Disc Prosthesis Does Not Alter the Outcomes

Baptiste Boukebous, Lorenzo Serfaty, Oussema Abdelhedi, Mohamed Zoghlami, Cedric Maillot,Jean-yves Lazennec,Marc-Antoine Rousseau

INTERNATIONAL JOURNAL OF SPINE SURGERY(2023)

引用 0|浏览1
暂无评分
摘要
Background: While first-generation articulated disc prostheses had an ideal positioning schematically as posterior as possible because of their geometrically determined center of rotation, the dogma may change for viscoelastic implants, whose center of rotation is free. Our hypothesis was to assess whether the anteroposterior positioning (APP) of a viscoelastic implant may influence the clinical or radiological outcomes at follow -up. Methods: Twenty -five patients (mean age 47 years) were evaluated, with an average follow -up of 25.9 months. The primary outcome was the implants' APP on lateral radiographs. APP between 0% and 49% meant anterior centering, 50% perfect centering, and 51% to 100% posterior centering. The cohort was divided into 2 groups: anterior positioning and posterior positioning. Measurements were performed blindly to the functional outcomes. Visual analog scale for neck pain and radicular pain and the Neck Disability Index were assessed. Range of motion was measured at the last follow -up. The C2 to C7 Cobb angle and the spinocranial angle were also measured. Results: The median crude offset from the vertebral endplate center was 0.4 mm (mean: 0.3 mm, Q1: -1.5 mm, Q3: 2 mm; range, -2.9 to 4 mm). The mean overall APP was 49%, 45.2% (95% CI, 43.2%-47.1%) in the anterior group, and 54.1% (95% CI, 51.4%-55.3%) in the posterior group. Fifteen patients were in the group anterior positioning and 10 in the group posterior positioning. The mean spinocranial angle was 79 degrees preoperatively and 74 degrees preoperatively (P = 0.04). Functional outcomes were significantly improved at the last follow -up (P < 10-4). There was no significant correlation between the APP, functional outcomes, and range of motion. Conclusion: The APP of the CP -ESP viscoelastic disc arthroplasty does not significantly influence the clinical or radiological outcomes at follow -up. This study suggests that this type of implant tolerates greater variability in its implantation technique.Level of Evidence: 4.
更多
查看译文
关键词
cervical disc arthroplasties,unconstrained prostheses,anteroposterior positioning,functional outcomes,sagittal alignment
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要