First randomised controlled trial comparing the sirolimus- eluting bioadaptor with the zotarolimus-eluting drug-eluting stent in patients with de novo coronary artery lesions: 12-month clinical and imaging data from the multi-centre, international, BIODAPTOR-RCT

ECLINICALMEDICINE(2023)

引用 1|浏览7
暂无评分
摘要
Background The DynamX (TM) bioadaptor is the first coronary implant technology with a unique mechanism unlocking the bioadaptor frame after polymer resorption over 6 months, uncaging the vessel while maintaining dynamic support to the vessel. It aims to achieve the acute performance of drug-eluting stents (DES) with the advantages of restoration of vessel function. Methods This international, single blinded, randomised controlled (1:1) trial compared a sirolimus-eluting bioadaptor with a contemporary zotarolimus-eluting stent (DES) in 34 hospitals in Europe, Japan and New Zealand. Patients with de novo coronary lesions and absence of acute myocardial infarction were enrolled from January 2021 Feburary 2022. The implantation of the bioadaptor followed the standards of DES. An imaging subset of 100 patients had angiographic and intravascular ultrasound assessments, and 20 patients additionally optical coherence tomography. Data collection will continue through 5 years, we herein report 12-month data based on an intention-to-treat population. This trial is registered at ClinicalTrials.gov (NCT04192747). Findings 445 patients were randomised between January 2021 and February 2022. Device, lesion and procedural success rates, and acute gain were similar amongst the groups. The primary endpoint, 12-month target lesion failure, was 1.8% [95% CI: 0.5; 4.6] (n = 4) versus 2.8% [95% CI: 1.0; 6.0] (n = 6), p(non-inferiority) < 0.001 for the bioadaptor and the DES, respectively (Delta-1.0% [95% CI: -3.3; 1.4]). One definite or probable device thrombosis occurred in each group. The 12-month imaging endpoints showed superior effectiveness of the bioadaptor such as in-device late lumen loss (0.09 mm [SD 0.34] versus 0.25 mm [SD 0.39], p = 0.04), and restored compliance and cyclic pulsatility (%mid in-device lumen area change of 7.5% versus 2.7%, p < 0.001). Interpretation This is the first randomised controlled trial comparing the novel bioadaptor technology against contemporary DES. The bioadaptor demonstrated similar acute performance and 12-month clinical outcomes, superior imaging endpoints including restoration of vessel function. Funding The study was funded by Elixir Medical. Copyright (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
更多
查看译文
关键词
Bioadaptor,Percutaneous coronary intervention,Coronary artery disease,Drug-eluting stents,Cyclic pulsatility,Vessel function
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要