Composite slab floors made of cross laminated timber and ultra high-performance concrete: Early-age deflection, stripping time, and its implication on the structural performances

ENGINEERING STRUCTURES(2023)

引用 0|浏览0
暂无评分
摘要
•The short-term deflection of the CLT-UHPC floor without shoring reached 50 % of the maximum allowed.•UHPC shrinkage causes 75 % of the short-term deflection.•UHPC shrinkage reduced the effective bending stiffness of 35 %.•A discretized solution based the effective modulus has been developed to predict the short-term deflection.•The developed analytical model allows estimating the optimal stripping time.•CLT-UHPC floor of 10 m with a shoring removal time 2 days after casting can be designed.
更多
查看译文
关键词
Timber-concrete composite floor,Cross-laminated timber,Ultra-high-performance concrete,Autogenous shrinkage,Creep,Effective modulus,Short-term deflection,Multi-criteria design