Non-contrast based approach for liver function quantification using Bayesian-based intravoxel incoherent motion diffusion weighted imaging: A pilot study

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS(2023)

引用 0|浏览5
暂无评分
摘要
Purpose: Liver cirrhosis disrupts liver function and tissue perfusion, detectable by magnetic resonance imaging (MRI). Assessing liver function at the voxel level with 13-b value intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) could aid in radiation therapy liver-sparing treatment for patients with early impairment. This study aimed to evaluate the feasibility of IVIM-DWI for liver function assessment and correlate it with other multiparametric (mp) MRI methods at the voxel level.Method: This study investigates the variability of apparent diffusion coefficient (ADC) derived from 13-b value IVIM-DWI and B1-corrected dual flip angle (DFA) T1 mapping. Experiments were conducted in-vitro with QIBA and NIST phantoms and in 10 healthy volunteers for IVIM-DWI. Additionally, 12 patients underwent an mp-MRI examination. The imaging protocol included a 13-b value IVIM-DWI sequence for generating IVIM parametric maps. B1-corrected DFA T1 pulse sequence was used for generating T1 maps, and Gadoxatate low temporal resolution dynamic contrast-enhanced (LTR-DCE) MRI was used for generating the Hepatic extraction fraction (HEF) map. The Mann-Whitney U test was employed to compare IVIM-DWI parameters (Pure Diffusion, D-slow ; Pseudo diffusion, D-fast ; and Perfusion Fraction, F-p ) between the healthy volunteer and patient groups. Furthermore, in the patient group, statistical correlations were assessed at a voxel level between LTR-DCE MRI-derived HEF, T1 post-Gadoxetate administration, Delta T1%, and various IVIM parameters using Pearson correlation.Results: For-vitro measurements, the maximum coefficient of variation of the ADC and T1 parameters was 12.4% and 16.1%, respectively. The results also showed that F-p and D-fast were able to distinguish between healthy liver function and mild liver function impairment at the global level, with p = 0.002 for F-p and p < 0.001 for D-fast . Within the patient group, these parameters also exhibited a moderate correlation with HEF at the voxel level.Conclusion: Overall, the study highlighted the potential of D-fast and F-p for detecting liver function impairment at both global and pixel levels.
更多
查看译文
关键词
liver function quantification,incoherent motion diffusion
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要