Non-uniform Current Distribution in Parallel-Wound No-Insulation High-Temperature Superconductor Coil During Ramping and Fast Discharging Operations

Superconductor science and technology/Superconductor science & technology(2023)

引用 0|浏览0
暂无评分
摘要
A parallel-wound no-insulation (PWNI) high-temperature superconductor (HTS) coil is a kind of pancake-shaped no-insulation (NI) coil wound with parallel-stacked HTS tapes, which combines the characteristics of a NI coil and non-twisted stacked-tape cable. It shows a significant advantage in accelerating the ramping response compared with traditional NI HTS coils wound by a single tape, and is a promising alternative for large-scale high-field magnets. The stacked cable approach can lead to current redistribution between parallel tapes during ramping operations. It couples with the turn-to-turn current redistribution and leads to a much more complicated current redistribution inside the PWNI coil, the mechanism of which remains unclear so far. The aim of this work is to investigate electromagnetic behavior of a PWNI HTS coil in ramping and fast discharging process. A simulation model was developed by integrating an equivalent circuit network model and an improved T-A model. A three-tape PWNI coil and its insulated counterpart were wound and tested, and this model was validated by charging and discharging tests. Results show that there is a significant non-uniform current distribution on parallel tapes in the same turn during ramping operations and the maximum azimuthal current (transport current) can be 2.26 times the minimum one in the three-tape PWNI coil in this study. Meanwhile, the radial current shows a considerable accumulation in the tape near turn-to-turn contacts and the radial current through the turn-to-turn contacts can be 4.16 times of that the flow through tape-to-tape contacts (parallel tapes) in the same turn. During the fast discharging process, a significant coupling current is generated in the PWNI coil, leading to a large opposite transport current in local areas; the amplitude of variation of this can be 4.66 times the initial operating current. The radial current shows a similar distribution but opposite direction to that during ramping, and its amplitude is two orders of magnitude higher. These results provide practical guidelines for the design of large-scale high-field HTS magnets.
更多
查看译文
关键词
parallel-wound no-insulation (PWNI) coil,equivalent circuit network model,current redistribution,ramping behaviors
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要