Refractive errors occurring with tilt of intraocular lenses

OPHTHALMIC AND PHYSIOLOGICAL OPTICS(2024)

引用 0|浏览6
暂无评分
摘要
A thin lens technique was developed to determine how the effective powers of toric monofocal intraocular lenses (IOLs) are influenced by tilt and the refractive errors associated with the tilt. A series of steps determined the effective power of the cornea at the IOL, the IOL power, the effective power of the tilted IOL, the correction required at the front of the eye and the power of an IOL that would compensate for the tilt. The correction was determined by starting at the ideal reduced image vergence at the IOL, backwards raytracing to obtain a reduced image vergence at the cornea, and subtracting the cornea power from this reduced image vergence. Examples are presented for different situations where the IOL is either tilted about the vertical or an oblique axis. Raytracing with a thick lens verified the accuracy of the technique.
更多
查看译文
关键词
intraocular lens power,lens tilt,raytracing