谷歌浏览器插件
订阅小程序
在清言上使用

Hemodynamic analysis of unilateral and bilateral renal artery stenosis based on fluid-structure interaction

Computer methods in biomechanics and biomedical engineering(2023)

引用 0|浏览7
暂无评分
摘要
Renal artery stenosis (RAS) hypertension is a common type of secondary hypertension. This paper aimed to explore how unilateral renal artery stenosis (Uni-RAS) and bilateral renal artery stenosis (Bi-RAS) caused renovascular hypertension with the fluid-structure interaction (FSI) method. Based on a real RAS model, 20 ideal models with different stenosis degrees were established by modifying the stenosis segment. The hemodynamic parameters at different degrees of stenosis, mass flow rate (MFR), pressure drop (PD), fractional flow reserve (FFR), oscillatory shear index (OSI), and relative residence time (RRT), were numerically calculated by the computational fluid dynamics (CFD) method. The numerical results showed that RAS caused the decrease of MFR, and the increase of PD and the proportion of high OSI and high RRT. In the case of RAS, it could not be regarded as a reference indicator for causing renovascular hypertension that the value of FFR was greater than 0.9. In addition, the results of the statistical analysis indicated that Uni-RAS and Bi-RAS were statistically different for MFR, PD and the proportion of high RRT.
更多
查看译文
关键词
Uni-RAS,Bi-RAS,renovascular hypertension,computational fluid dynamics,fluid-structure interaction
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要