Introduction:Liquid biopsies are increasingly being adopted in the care of patients with cancer. Not only in patients with metastatic disease but the utility is also being recognized in earlier phases of the journey of a patient with cancer. More recently, methylated platforms are offering another lens of looking at the same question more so in minimal residual disease (MRD) and early detection settings. While false positives secondary to clonal hematopoiesis of indeterminate potential (CHIP) are recognized as one entity to consider when interpreting these assays, and advanced CHIP filtering bioinformatics platforms can prevent this, false positives secondary to aberrant methylation are not described. Case Presentation:Herein, we report a case of a patient with hepatitis C-related viremia and a very high viral load that had a false-positive plasma-only colorectal MRD assay. The colorectal MRD assay spontaneously cleared on hepatitis C virus therapy which led to clearance of the virus. Conclusion:As these assays are increasingly applied in real-world settings, it would be of value to consider non-cancer chronic disease states that may lead to aberrant methylation that could lead to a false-positive assay.