Development and validation of a deep-learning model for the detection of non-displaced femoral neck fractures with anteroposterior and lateral hip radiographs

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY(2023)

引用 0|浏览5
暂无评分
摘要
Background: Hip fractures, including femoral neck fractures, are a significant cause of morbidity and mortality in the elderly population and are typically diagnosed using plain radiography. However, diagnosing non-displaced femoral neck fractures can be challenging due to their subtle appearance on hip radiographs. Previous deep-learning models have shown low accuracy in identifying these fractures on anteroposterior (AP) radiographs; however, no studies have used lateral radiographs. This study aimed to evaluate the potential of using deep-learning with both AP and lateral hip radiographs to automatically identify non-displaced femoral neck fractures.Methods: We conducted a retrospective analysis of patients with femoral neck fractures at The First Affiliated Hospital of Xiamen University. All the hip radiographs were reviewed, and cases of non-displaced femoral neck fractures were included in the study. Additionally, 439 participants with normal hip radiographs were also included in the study. A vision transformer (Vit) model was developed using 1,536 AP and lateral hip radiograph. The model's performance was compared to the performance of two groups of human observers: an expert group comprising orthopedic surgeons and radiologists, and a non-expert group, including emergency physicians and general practice doctors. We also carried out the external validation using two additional data sets to assess the generalizability of the model.Results: The Vit model showed exceptional performance in detecting non-displaced femoral neck fractures on paired AP and lateral hip radiographs, achieving a binary accuracy of 95.8% [95% confidence interval (CI): 94.9%, 96.8%] and an area under the curve (AUC) of 0.988. Compared to the human observers, the model had a higher accuracy of 96.7% (95% CI: 93.9%, 99.5%) on the paired AP and lateral hip radiographs, while the accuracy of the expert group was 90.5% (95% CI: 85.7%, 95.2%). Further, the model maintained good performance during the external validation, with an AUC of 0.959 on the paired AP and lateral views.Conclusions: Our Vit model showed expert-level performance in identifying non-displaced femoral neck fractures on paired AP and lateral hip radiographs. This model has the potential to enhance diagnosis accuracy and improve patient outcomes by reducing the need for additional examinations and preoperative time.
更多
查看译文
关键词
Deep learning, femoral neck fracture, vision transformer (Vit)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要