Use of the Napoleon to Improve Polyp Measurement in Gastroenterology Fellows

Sigrid Young,Sandy Ng,Briton Lee, Amanda Jurewicz,Cameron Zenger, Nikhil Mehta,Adam J. Goodman,Violeta Popov,Renee Williams

The American Journal of Gastroenterology(2023)

引用 0|浏览1
暂无评分
摘要
Introduction: Colorectal cancer (CRC) is the third most commonly diagnosed cancer in the US. Screening by colonoscopy has reduced CRC incidence, and colonoscopy findings (polyp number, size, and histology) are used to guide recommendations for surveillance. However, there are inaccuracies in endoscopists’ measurement of polyp size, which can adversely affect surveillance intervals. Prior studies of gastroenterology attendings have shown that accuracy improves with greater years of experience and endoscopic measurement devices. However, there is limited data on polyp measurements among fellows. This study assesses gastroenterology fellows’ accuracy in colonic polyp measurement by visual assessment (standard of care) versus an endoscopic measurement device (Napoleon). Methods: This device trial utilized Micro-Tech’s Endoscopic Polyp Measurement Device (Ann Arbor, MI) named Napoleon, which is a catheter with a 15mm ruler, to measure polyp size. This study included inpatient and outpatient colonoscopies performed by gastroenterology fellows at two urban facilities from June 2021 to May 2023. We assessed the difference in polyp measurement between fellows performing a visual assessment and utilization of the Napoleon device, which provides a direct measurement of polyp size. Wilcoxon signed-rank test was used to analyze the differences in measurements (Table 1, Figure 1). Results: Eleven fellows participated in the study. In total, 42 polyps were evaluated across 35 patients. Seventeen polyps were assessed by first-year fellows, 22 by second-year fellows, and 3 by third-year fellows. There was a significant difference between visual estimation of the polyps and Napoleon measurements (P = 0.006). First, second, and third-year fellows had on average a 1.05mm difference in size between visual assessment and Napoleon measurement. Fellows tended to overestimate polyp size compared to Napoleon measurement. In two procedures, the Napoleon polyp measurement was < 10mm in size, which would have extended recommended surveillance time. Fellows on average took an extra minute per polyp to use the Napoleon device. Besides increased procedural time, no other adverse effects were observed. Conclusion: Fellows tended to overestimate polyp size on visual assessment compared to measurement with Napoleon, an endoscopic ruler. Napoleon can offer a more accurate assessment of polyp size, which affects recommended surveillance interval time. Given the small sample size, more polyps are still needed to validate the above results.Figure 1.: The Napoleon Device is a “Little Ruler” to Endoscopically Measure Polyp Size. Table 1. - Among a Sample Size of 42 Polyps, Mean Polyp Size With Visualization Was on Average 1.05mm Greater Than That Measured With the Napoleon Device, Which Was Statistically Significant (P=0.006) Mean Difference in Polyp Size by Visual Inspection vs Napoleon Measurement P-value 1.05 mm 0.006 In 2 cases, the Napoleon measurement was <10 mm, which would have extended the recommended interval surveillance time.
更多
查看译文
关键词
polyp measurement,gastroenterology fellows
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要