Mp26-12 a comparative analysis of ergonomic risk utilizing the 4k-3d exoscope versus standard operating microscope for male fertility microsurgery

The Journal of Urology(2023)

引用 0|浏览6
暂无评分
摘要
You have accessJournal of UrologyCME1 Apr 2023MP26-12 A COMPARATIVE ANALYSIS OF ERGONOMIC RISK UTILIZING THE 4K-3D EXOSCOPE VERSUS STANDARD OPERATING MICROSCOPE FOR MALE FERTILITY MICROSURGERY Nicholas Deebel, Rohit Reddy, Alexander Weber, Kevin Chu, Jesse Ory, Ryan Terlecki, and Ranjith Ramasamy Nicholas DeebelNicholas Deebel More articles by this author , Rohit ReddyRohit Reddy More articles by this author , Alexander WeberAlexander Weber More articles by this author , Kevin ChuKevin Chu More articles by this author , Jesse OryJesse Ory More articles by this author , Ryan TerleckiRyan Terlecki More articles by this author , and Ranjith RamasamyRanjith Ramasamy More articles by this author View All Author Informationhttps://doi.org/10.1097/JU.0000000000003254.12AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: The standard operating microscope (OM) places microsurgeons in uncomfortable and risky positions. The 4K-3D exoscope lacks eyepieces allowing for a “heads up” posture. Additionally, surgeons may maintain a more “neutral” upper arm position. We aim to stratify ergonomic risk amongst infertility surgeons using the 4K-3D exoscope versus the OM with wearable technology. METHODS: The surgeon was calibrated with wearable sensor inertial measurement units (IMUs) on the head and upper arms. Each IMU contained an accelerometer, magnetometer, and gyroscope to measure surgeon joint angle change during microscopic procedures for male fertility. The validated modified rapid upper limb assessment was used to determine the proportion of time spent in ranges of risk. Categories 1-4 were assigned for the head and upper extremities (4= highest ergonomic risk) (Figure 1). Chi-squared analysis was used to test proportions. RESULTS: A total of 500 and 479 microsurgical minutes from 4K-3D exoscope and OM guided surgeries were analyzed. The 4K-3D exoscope significantly favored upper arm category 1 positioning compared to the OM (56.2% vs. 37.7%; p < 0.0001) (Figure 2). The OM exposed the surgeon to higher category 3 positioning (14.6% vs. 1.6%; p <0.0001). More time was spent with the neck “extended” using the 4K-3D exoscope (51.8% vs. 19.5%; p < 0.0001). During 4K-3D exoscope use, 67% of neck extension time was between 0-10 degrees (category 1). Only 1% of 4K-3D exoscope operative time was spent with the neck in the high-risk interval (category 4). When considering both neck extension and flexion, more time was spent in risk group 1 and 2 with the operating microscope (p < 0.0001). CONCLUSIONS: The 4K-3D exoscope offers favorable ergonomic positioning for the upper extremities which may reduce work stress related injury. More operative time was spent with the neck in mild extension with 4K-3D exoscope use. However, the OM favored longer operative times in low-risk neck ergonomic positions. Source of Funding: Investigator initiated funding from Olympus. NIH Grant R01 DK130991 and Clinician Scientist Development Grant from the ACS to RR © 2023 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 209Issue Supplement 4April 2023Page: e357 Advertisement Copyright & Permissions© 2023 by American Urological Association Education and Research, Inc.Metrics Author Information Nicholas Deebel More articles by this author Rohit Reddy More articles by this author Alexander Weber More articles by this author Kevin Chu More articles by this author Jesse Ory More articles by this author Ryan Terlecki More articles by this author Ranjith Ramasamy More articles by this author Expand All Advertisement PDF downloadLoading ...
更多
查看译文
关键词
exoscope,standard operating microscope,ergonomic risk,male fertility
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要