A Simple Magnetic-Flux-Based Method for Localizing High-Resistance Stator Ground Faults in Synchronous Machines

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS(2024)

引用 0|浏览1
暂无评分
摘要
This article presents a new offline method based on the analysis of the magnetic flux to determine the location of stator ground faults in synchronous machines. First, the defective phase is identified via the insulation resistance (Megger) test, and then the longitudinal axis of the rotor is aligned with the faulty phase winding. During two measuring modes, a voltage is applied separately to each end of the faulty phase while the other end is floating and the core is grounded. The application of the voltage between each terminal of the faulty phase and ground will lead to the circulation of a current through the stator winding to the fault point, being its path closed by the grounded core. A magnetic flux will then be created, which can be sensed indirectly by measuring the induced voltage in the rotor field winding. The fault point can be identified by measuring the applied current or voltage and the magnetic flux created in both measuring modes. Since stator ground faults usually occur via high resistances, the method is extended for the detection of such faults by processing the data using the stationary wavelet transform. The experimental results show that the proposed method is very sensitive and is able to identify the ground fault location for fault resistances up to a few hundred of kiloohm.
更多
查看译文
关键词
Fault location,stator ground fault,synchronous machine (SM),wavelet transform