Different fixation methods in anterior cruciate ligament reconstruction (ACLR) have been associated with different revision rates, specifically in the early postoperative period. However, most previous research has either grouped together different fixation types or evaluated femoral-sided fixation or tibial-sided fixation separately. Therefore, the purpose of this study was to determine ACL revision rates for specific combinations of femoral and tibial fixation methods within 2 years of primary hamstring tendon autograft ACLR based on data from the Swedish National Knee Ligament Registry (SNKLR). Patients that underwent primary hamstring tendon autograft ACLR between 2005 and 2018 in the SNKLR were included. The collected data included patient characteristics (age, sex, body mass index [BMI]), activity at time of injury, surgical information (concomitant injuries, time from injury to surgery, fixation types at the femur and tibia), and subsequent revision ACLR. Revision rate within 2 years of the index procedure was chosen, as ACLR fixation is most likely to contribute to ACLR revision within the first 2 years, during graft maturation. Of the 23,238 included patients undergoing primary hamstring ACLR, 581 (2.5