Evaluating an enhanced thermal response test (ETRT) with high groundwater flow

Anna Albers,Hagen Steger, Roman Zorn,Philipp Blum

Geothermal Energy(2024)

引用 0|浏览1
暂无评分
摘要
Enhanced thermal response tests (ETRT) enable the evaluation of depth-specific effective thermal conductivities. Groundwater flow can significantly influence the interpretation of ETRT results. Hence, this study aims to critically evaluate an ETRT with high groundwater flow (> 0.2 m d−1). Different approaches in determining the specific heat load of an ETRT are compared. The results show that assuming constant electrical resistance of the heating cable with time can account for an inaccuracy of 12
更多
查看译文
关键词
Actively heated fibre optic,Borehole heat exchanger (BHE),Distributed temperature sensing (DTS),Effective thermal conductivity,Heating cable,Thermal response test (TRT)