A retrospective study of non-equidistant interstitial brain CT perfusion scanning and prediction of time to peak

Yaxin Duan, Jia Yao,Yingjian Jiang, Wen Sun,Fengtan Li

HELIYON(2024)

引用 0|浏览2
暂无评分
摘要
Background: Eexploring the limits of CT cranial perfusion scan acquisition intervals and predicting time to peak. Methods: A retrospective analysis was conducted on 45 patients with suspected stroke who underwent brain CTP scans. Different sampling intervals were set based on the TDC. The patients were divided into four groups: Group 1 underwent continuous scanning with a uniform interval of 1.5 s; Group 2 had a uniform interval of 3 s; Group 3 had a 1.5-s interval between arterial and venous peak vertices with 1 point retained before and after the peak for 1.5 s and with a remaining acquisition interval of 4.5 s; and Group 4 had a uniform interval of 4.5 s. Statistical analysis was performed on the perfusion parameters of each group. Additionally, in 286 patients who underwent head and neck CTA examinations, the peak time of contrast medium was recorded, and the peak time was predicted based on factors such as age, height, weight, heart rate, systolic blood pressure, diastolic blood pressure, triglycerides, and total cholesterol. The results compared with Group 1 and Group 2, as well as Group 1 and Group 3, the P values of CBF, CBV, MTT, and Tmax in the left and right cerebral hemispheres of healthy subjects and in the infarct and noninfarct areas of patients were all >0.05. A comparison between Group 1 and Group 4 showed that right cerebral hemisphere CBF and CBV, left cerebral hemisphere CBF, CBV, and Tmax, infarct area CBV and Tmax, and noninfarct area CBF, CBV, and MTT had P values > 0.05, while other groups all had P values < 0.05. Bland-Altman analysis showed that the perfusion parameters in Group 1 were consistent with those in Group 2, and those in Group 1 were consistent with those in Group 3. The radiation doses in the second and third groups were lower, and the dose in the third group was lower than that in the second group. Conclusion: Continuous acquisition between the peak points of the arterial and venous phases, with 1 point reserved before and after the peak and a 4.5-s interval for the rest, represents the maximum time interval for CTP scanning and can effectively reduce the radiation dose. The formula Tmax (s) = 0.290 x height (cm) - 0.226 x heart rate (times/min) + 0.216 x age (years) - 1.901 x triglycerides (mmol/L) - 0.061 x systolic blood pressure (mmHg) - 7.216 (R2 = 0.449, F = 17.905, P < 0.01) was established for predicting time to peak enhancement.
更多
查看译文
关键词
Cerebral CT perfusion,CTA,Quantitative CT perfusion,Stroke,Brain
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要