Arterial Blood Flow and Effects on Limb Tissue Perfusion During Endoshunting of the Common Iliac Artery in an Experimental Porcine Model

Johan Millinger,Marcus Langenskioeld,Andreas Nygren,Klas Osterberg, Joakim Nordanstig

EJVES VASCULAR FORUM(2024)

引用 0|浏览2
暂无评分
摘要
Objective: Temporary arterial shunting is an established method to prevent tissue ischaemia. Although less well established, shunting might also be achieved through endovascular and hybrid techniques, known as endoshunting. Endoshunting offers advantages, for example, enabling minimally invasive access and avoiding complete occlusion of the donor artery. In an ex vivo bench test, volume flow in various interconnected endoshunt systems has been tested previously. This study aimed to investigate the capacity of the best performing endoshunt system in vivo. Methods: Six anaesthetised pigs had their common iliac arteries (CIAs) explored, with the left CIA serving as the experimental and the right CIA as the control. Mean arterial pressure, regional blood flow, endoshunt flow, and regional oxygen extraction and lactate production were recorded. Distal muscle perfusion was monitored using near infrared spectroscopy (NIRS). Each experiment involved baseline registration, cross clamping of the left CIA, a 120 minute endoshunt session, and restoration of native flow. Results: During cross clamping, NIRS values on the experimental side reached the lowest measurable value. Following endoshunt activation, there were no NIRS value differences between the experimental and control extremities whereas the average arterial flow decreased in both the experimental (270-140 mL/min, p = .028) and control extremities (245-190 mL/min, p = .25), with a greater drop on the endoshunted side (48% vs. 22%, respectively). Lactate levels temporarily increased by 42% in the endoshunted limb on endoshunt activation but were normalised within an hour. Oxygen extraction remained constant at 55% on the control side but increased to 70% on the endoshunted side (p = .068). Conclusion: In this animal model, a flow optimised endoshunt system appeared to provide sufficient blood flow and restored stable tissue perfusion. Although arterial flow was slightly lower and oxygen extraction slightly higher on the endoshunted side, the endoshunt seemed to deliver adequate perfusion to prevent significant ischaemia. (c) 2024 The Author(s). Published by Elsevier Ltd on behalf of European Society for Vascular Surgery. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Article history: Received 30 August 2023, Revised 10 December 2023, Accepted 22 January 2024,
更多
查看译文
关键词
Endovascular procedures,Ischaemia,Lower extremity,Near infrared spectroscopy,Perfusion,Vascular surgical procedures
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要