Thermal analysis of tubular daylight guidance system on an insulated flat roof with overlying soil

Hanlin Li,Dan Wu,Yanping Yuan

SOLAR ENERGY(2024)

引用 0|浏览2
暂无评分
摘要
As an emerging passive daylighting technology, tubular daylight guidance systems (TDGSs) are increasingly used in low-energy buildings. However, TDGS may become a thermal bridge to increase indoor air conditioning load. To avoid an increase in total energy consumption, the thermal analysis of a flat roof section with a TDGS is simulated using CFD in this work. Additionally, the simulation compares the heat transfer performance of a conventional TDGS with eight different designs TDGS that contain additional glass unit. The findings show that TDGS has a thermal bridging effect on an insulated flat roof with overlying soil. The additional glass unit in the middle of the conventional TDGS with diameter 500 mm decreases its overall heat transfer coefficient by 53 %. Further, the same thickness of glass is divided into 4 layers and evenly distributed inside the TDGS with diameter 500 mm, which can reduce the total heat transfer coefficient of the conventional TDGS by 67 %.
更多
查看译文
关键词
Tubular daylight guidance system,CFD simulation,Heat transfer,Thermal bridge,Underground space