Utilization of an Endobronchial Blocker Through a Double-Lumen Tube as Rescue for Inadequate One-Lung Ventilation

Jonathan E. Tang, Colton T. Roessner, Robert D. Stocum,Erica J. Stein,Michael K. Essandoh, Desmond M. D'Souza

SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA(2024)

引用 0|浏览2
暂无评分
摘要
Failure to provide one-lung ventilation can prohibit minimally invasive thoracic surgeries. Strategies for one-lung ventilation include double-lumen endotracheal tubes or endobronchial blockers, but rarely both. Inability to provide lung isolation after double-lumen endotracheal tube placement requires troubleshooting and sometimes the use of extra equipment. This case describes using a unique Y-shaped endobronchial blocker placed through a left-sided double-lumen endotracheal tube after failure to achieve lung isolation with a double-lumen endotracheal tube alone.
更多
查看译文
关键词
thoracic surgery,airway management,one-lung ventilation,double-lumen tube,endobronchial blocker,EZ-blocker,cardiothoracic anesthesia,cardiothoracic surgery,thoracic anesthesia